• 100% Black-owned, Level 1 B-BBEE

Mineral Separation Spiral Concentrators: Selection Guide for South African Plants

Mineral Separation Spiral Concentrators: Selection Guide for South African Plants
17May

Mineral Separation Spiral Concentrators: Selection Guide for South African Plants

A mineral separation spiral concentrator splits a slurry by particle density as it flows down a helical trough: heavy grains move to the inner edge, light grains and slimes move to the outer rim, and adjustable splitters cut the flow into concentrate, middlings and tailings. Spirals suit liberated feed between about 0.1 mm and 3 mm with a clear density difference between the valuable mineral and the gangue. Selecting one comes down to four checks: the density contrast of your minerals, the size range of the feed, the tonnage per start, and the trough profile matched to the duty.

How a spiral concentrator separates minerals

Slurry enters the top of the spiral and flows down the trough as a thin film, usually only a few millimetres to about 15 mm deep. Three effects act on each particle at once: gravity pulls it towards the trough floor, centrifugal force from the curved path pushes it outward, and fluid drag carries it downstream. Heavy and coarse particles settle quickly into the slow-moving layer against the floor. Friction holds them back, so they lose the centrifugal push and drift towards the centre column.

Light particles stay suspended in the faster upper layer and are flung outward. A secondary circulation forms across the trough, running inward along the floor and outward near the surface, and this keeps sorting the bed over every turn. By the last turn the slurry has formed bands across the trough width, as shown below.

Cross-section of a spiral concentrator trough showing heavy minerals near the centre column, middlings in the middle and light gangue and slimes at the outer rim, with two splitter positions
Heavy grains collect in the slow inner film; splitter positions decide what reports to concentrate, middlings and tailings.

Splitters at the lower turns (and on some profiles, concentrate ports at intermediate turns) divert each band into a separate launder. Moving a splitter inward raises concentrate grade and lowers recovery. Moving it outward does the opposite. That single adjustment is the main control an operator has once the feed is fixed.

Check the density contrast before you choose a spiral

The quickest screening test is the concentration criterion (CC), a ratio that uses the specific gravity (SG) of the two minerals in water: CC = (SG of heavy mineral - 1) / (SG of light mineral - 1). The rule of thumb published in Wills Mineral Processing Technology is that a CC above 2.5 allows efficient gravity separation down to about 75 µm, 1.75 to 2.5 works down to about 150 µm, and 1.5 to 1.75 is only reliable at coarse sizes.

Bar chart of concentration criterion values: coal vs shale 4.29, hematite vs quartz 2.58, ilmenite vs quartz 2.25, chromite vs plagioclase 2.06, chromite vs pyroxene 1.52
The lower the criterion, the coarser the particle size at which a spiral stays efficient. Chromite against pyroxene is the hard case.

Hematite and magnetite against quartz sit above 2.5, which is why iron ore spirals can reject silica at fine sizes. Ilmenite, zircon and rutile against quartz sit between 2.0 and 2.3, so mineral sands circuits need several cleaning stages. Chromite against plagioclase is close to 2.1, but chromite against pyroxene drops to about 1.5. In UG2 and LG6 chrome ores the pyroxene is what limits the final silica grade, and it is the reason chrome plants run cleaner and recleaner spirals instead of a single pass.

The criterion is a guide, not a guarantee. Spirals routinely work below these sizes on well-deslimed feed, but separation efficiency falls as the CC drops, and particle shape matters: flat mica or platy hematite behaves lighter than its SG suggests.

Spiral design variables and what each one changes

Once the ore passes the density check, the trough design decides capacity and sharpness. The table gives commonly specified ranges and the effect of each variable.

VariableTypical rangeEffect on separation
Trough diameter600-950 mm (Songatech models); up to about 1 m in industryLarger diameter gives more trough area per turn and higher capacity per start, with a slightly coarser effective size range
Number of turns5-7 turnsMore turns give the bands more time to form. Cleaners and fine feeds benefit most
Pitch (drop per turn)Varies by profileSteeper pitch raises flow velocity and capacity; flatter pitch suits low-density cuts such as coal
Starts per columnSingle, double or tripleTwo or three troughs on one column multiply capacity in the same floor area
Capacity per startApproximately 0.3-4 t/h, ore dependentOverloading thickens the film and drags heavies outward; underloading lets light grains settle into the concentrate band
Feed solidsCommonly about 15-45% solids by mass; chrome roughers often 30-50%Too dilute and the film moves too fast; too dense and the bed cannot stratify
Wash waterZero on most modern profiles; wash-water rings where fittedFlushes light grains out of the concentrate band, raising grade at a small loss of recovery
Wear surfacePolyurethane or ceramic on a fibreglass bodyHolds the trough profile; a worn profile shifts the bands and the cut point

Songatech spirals use a fibreglass body with polyurethane or ceramic wear surfaces, 5 to 7 turns, single, double or triple starts, and adjustable splitters with optional wash-water rings and repulpers. Each unit is checked for pitch and radius, liner thickness, and distributor flow balance before dispatch.

Matching the trough profile to the duty

A spiral profile is designed for a stage in the circuit, not just for a mineral. Rougher profiles accept high tonnage and set splitters for recovery. Cleaner profiles run lighter loads and finer splitter positions to reach grade. Scavengers recover near-miss heavies from rougher tailings and run with open splitters.

Table of spiral set-up by duty: chrome rougher, chrome cleaner, iron ore rougher, coal fines and scavenger with feed size, starts, wash water and splitter settings
Starting configurations by duty. Feed size and density contrast set the profile; splitters are tuned on site.

Coal is the exception to the rule that the heavy fraction is the product. On coal fines spirals the clean coal reports to the outer bands and the shale and pyrite report inward, so the splitter is set to cut a low-density product at a relative density of roughly 1.6 to 2.0. The coal washing spirals guide explains where spirals sit relative to the dense medium cyclones in a coal plant.

Feed preparation: the part that decides performance

Most poor spiral results trace back to the feed, not the trough. Four controls matter.

Top size

Particles coarser than about 2 to 3 mm roll across the bands and settle in the wrong stream. Screen the feed to the top size of the profile, and send oversize back to milling or to a jig or dense medium circuit.

Slimes

Particles finer than about 75 µm do not stratify and raise the slurry viscosity, which carries heavies into the tailings. Deslime ahead of the spirals, usually with hydrocyclones cutting at 45 to 75 µm.

Constant feed rate and density

Spirals have no level control or recycle to absorb surges. Feed from a pump box with level control and a variable-speed pump, and measure density at the distributor rather than at the plant feed.

Even distribution

A bank of 24 starts will only perform if every start gets the same flow. Use a radial distributor with wear-resistant nozzles, and check the split by timing a bucket fill at each outlet. Songatech supplies slurry distributors and launders for this duty.

Spirals compared with other gravity separators

DeviceTypical size rangeCapacityPower and reagentsBest use
Spiral concentratorAbout 0.1-3 mm0.3-4 t/h per startNo motor on the spiral; pumping onlyBulk roughing and cleaning of fine, liberated heavy minerals
Shaking tableAbout 0.05-2 mmCommonly under 2 t/h per deckSmall drive motorFinal cleaning of small, high-value streams
JigAbout 0.5-25 mm and coarserHigh, per m² of bedPulsation drive, waterCoarse iron ore, manganese, coal
Dense medium cycloneAbout 0.5-50 mmHighMedium recovery circuit with magnetite or ferrosiliconSharp density cuts on coarse feed
Teeter bed separatorNarrow range, about 5:1 top to bottom sizePer m² of bedFluidising water, level controlFine coal and mineral sands where a sharper cut is needed

Spirals win where the feed is fine, the tonnage is large and operating cost has to stay low. They lose where the cut must be very sharp at a low density on coarse material, which is the job of dense medium separation using ferrosilicon or magnetite.

When a spiral is the wrong choice

  • The valuable mineral is not liberated at the spiral feed size. A spiral cannot upgrade locked particles; liberation testing comes first.
  • Most of the value sits below about 50 µm. Flotation, enhanced gravity or magnetic separation will recover more.
  • The CC is below about 1.5 at the size you need to treat.
  • Feed rate swings by more than about 15-20% and cannot be buffered by a surge tank or pump box control.

How to specify a spiral concentrator

  • Ore type and minerals present, with SG of the valuable mineral and main gangue minerals
  • Particle size distribution of the spiral feed (top size, d50 and % below 75 µm)
  • Head grade and target concentrate grade and recovery
  • Dry tonnage to the spirals (t/h) and feed solids (% by mass)
  • Circuit stage: rougher, cleaner, recleaner or scavenger
  • Available height and floor area for the bank, and the number of existing starts if retrofitting
  • Preferred wear surface (polyurethane or ceramic) and whether wash water is available
  • Distributor and launder arrangement: new, or matching an existing layout

Frequently asked questions

What is the difference between a single-start and a triple-start spiral?

A single-start column carries one trough. A triple-start column carries three troughs wound around the same centre column, so it treats about three times the tonnage in nearly the same floor area. Each trough still has its own splitters and must receive an equal share of the feed.

What particle size can a spiral concentrator treat?

Most spiral profiles treat about 0.1 mm to 3 mm, with the best results between about 0.3 mm and 2 mm on Songatech spirals. Fines below about 75 µm should be removed first because they do not stratify and they thicken the slurry.

How much tonnage does one spiral start handle?

Typically 0.3 to 4 t/h per start, depending on the ore density, particle size and the stage in the circuit. Roughers run at the higher end and cleaners at the lower end. The correct rate is found by testwork or by adjusting during commissioning.

Do spirals need wash water?

Many modern profiles run without wash water. Where wash-water rings are fitted, a small flow along the inner edge flushes light grains out of the concentrate band and lifts grade. Chrome rougher duties often use wash water at the second stage.

How long does a spiral trough last?

Life depends on the abrasiveness and tonnage of the feed and on the wear surface. Polyurethane surfaces wear gradually at the feed box and the inner concentrate band; ceramic surfaces resist sliding abrasion for longer. Measure the liner thickness at fixed points each shutdown and replace or refurbish before the profile changes the cut point.

To size a spiral bank for your ore, see the Songatech spiral concentrators range or send your feed data through the contact page for a quote.